Fx Copy
LaTeX Copy
Length of Wire DC is the measurement or extent of something from end to end. Check FAQs
l=V⋅Pline4⋅(C12)⋅(ρ)
l - Length of Wire DC?V - Volume Of Conductor?Pline - Line Losses?C1 - Current underground DC?ρ - Resistivity?

Length using Volume of Conductor Material (2-Wire Mid-Point DC US) Example

With values
With units
Only example

Here is how the Length using Volume of Conductor Material (2-Wire Mid-Point DC US) equation looks like with Values.

Here is how the Length using Volume of Conductor Material (2-Wire Mid-Point DC US) equation looks like with Units.

Here is how the Length using Volume of Conductor Material (2-Wire Mid-Point DC US) equation looks like.

185.2396Edit=35Edit⋅0.6Edit4⋅(3Edit2)⋅(1.7E-5Edit)
You are here -
Home » Engineering » Electrical » Power System » Length using Volume of Conductor Material (2-Wire Mid-Point DC US)

Length using Volume of Conductor Material (2-Wire Mid-Point DC US) Solution

Follow our step by step solution on how to calculate Length using Volume of Conductor Material (2-Wire Mid-Point DC US)?

FIRST Step Consider the formula
l=V⋅Pline4⋅(C12)⋅(ρ)
Next Step Substitute values of Variables
∴ l=35m³⋅0.6W4⋅(3A2)⋅(1.7E-5Ω*m)
Next Step Prepare to Evaluate
∴ l=35⋅0.64⋅(32)⋅(1.7E-5)
Next Step Evaluate
∴l=185.239643408737m
LAST Step Rounding Answer
∴l=185.2396m

Length using Volume of Conductor Material (2-Wire Mid-Point DC US) Formula Elements

Variables
Functions
Length of Wire DC
Length of Wire DC is the measurement or extent of something from end to end.
Symbol: l
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit: m³
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current underground DC
Current underground DC is defined as the current flowing through the overhead ac supply wire.
Symbol: C1
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Formula and 1500+ more formulas!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Formula and 1200+ more formulas!

Other Formulas to find Length of Wire DC

​Go Length using Area of X-Section (2-Wire Mid-Point Earthed DC US)
l=A⋅Pline⋅Vm22⋅(P2)⋅ρ

Other formulas in Wire Parameters category

​Go Line Losses using Area of X-Section (2-Wire Mid-Point Earthed DC US)
Pline=2⋅ρ⋅l⋅(P2)A⋅(Vm2⋅cos(θ)2)
​Go Line Losses using Volume of Conductor Material (2-Wire Mid-Point DC US)
Pline=4⋅ρ⋅P2⋅l2Vm2⋅V
​Go Area using Volume of Conductor Material (2-Wire Mid-Point DC US)
A=V2⋅l
​Go Volume of Conductor Material (2-Wire Mid-Point DC US)
V=4⋅ρ⋅(P2)⋅l2Pline⋅(Vm2)

How to Evaluate Length using Volume of Conductor Material (2-Wire Mid-Point DC US)?

Length using Volume of Conductor Material (2-Wire Mid-Point DC US) evaluator uses Length of Wire DC = sqrt((Volume Of Conductor*Line Losses)/(4*(Current underground DC^2)*(Resistivity))) to evaluate the Length of Wire DC, The Length using Volume of Conductor Material (2-wire Mid-point DC US) formula is defined as the total length of the wire that used in the 2-wire Mid-point earthed DC system. Length of Wire DC is denoted by l symbol.

How to evaluate Length using Volume of Conductor Material (2-Wire Mid-Point DC US) using this online evaluator? To use this online evaluator for Length using Volume of Conductor Material (2-Wire Mid-Point DC US), enter Volume Of Conductor (V), Line Losses (Pline), Current underground DC (C1) & Resistivity (ρ) and hit the calculate button.

FAQs on Length using Volume of Conductor Material (2-Wire Mid-Point DC US)

What is the formula to find Length using Volume of Conductor Material (2-Wire Mid-Point DC US)?
The formula of Length using Volume of Conductor Material (2-Wire Mid-Point DC US) is expressed as Length of Wire DC = sqrt((Volume Of Conductor*Line Losses)/(4*(Current underground DC^2)*(Resistivity))). Here is an example- 185.2396 = sqrt((35*0.6)/(4*(3^2)*(1.7E-05))).
How to calculate Length using Volume of Conductor Material (2-Wire Mid-Point DC US)?
With Volume Of Conductor (V), Line Losses (Pline), Current underground DC (C1) & Resistivity (ρ) we can find Length using Volume of Conductor Material (2-Wire Mid-Point DC US) using the formula - Length of Wire DC = sqrt((Volume Of Conductor*Line Losses)/(4*(Current underground DC^2)*(Resistivity))). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Length of Wire DC?
Here are the different ways to Calculate Length of Wire DC-
  • Length of Wire DC=Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*(Power Transmitted^2)*Resistivity)
Can the Length using Volume of Conductor Material (2-Wire Mid-Point DC US) be negative?
No, the Length using Volume of Conductor Material (2-Wire Mid-Point DC US), measured in Length cannot be negative.
Which unit is used to measure Length using Volume of Conductor Material (2-Wire Mid-Point DC US)?
Length using Volume of Conductor Material (2-Wire Mid-Point DC US) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Volume of Conductor Material (2-Wire Mid-Point DC US) can be measured.
© 2024-2026. Developed & Maintained by softUsvista Inc.
Copied!